Comtest Networks
CT-IG-MTAS192-2008-v1_8.doc
MTAS-192
38
Installation Guide June 2006
CONN-CLI:::1;
The response should be as follows:
Welcome to the MTAS CLI
For a list of commands, enter ‘?’
At this point, the user can type:
chk ethernet
This will display the existing settings for the MTAS-CM. To change the
settings, type the following:
ethernet
A series of settings and prompts will be displayed.
IP Address 10.0.2.100
New?
The user can either enter a new IP address or press <return> to keep the
existing value. The next prompt will be displayed.
Network Mask 255.255.255.0
New?
The user can either enter a new network mask or press <return> to keep the
existing value. The next prompt will be displayed.
Gateway 10.0.2.20
New?
The user can either enter a new gateway address or press <return> to keep
the existing value. The next prompt will be displayed.
DNS Server 0.0.0.0
New?
The user can either enter a new DNS server address or press <return> to keep
the existing value. The following message should appear and the user should
then log out.
IP Address 10.0.2.100
Network Mask 255.255.255.0
Gateway 10.0.2.20
DNS Server 0.0.0.0
Change will take effect on reset